Msa altair 4 x pdf splitter

Msa altair 4x operating manual pdf download manualslib. Msa offers a variety of test benches for your workshop with manual or. Hu altair 4xr gyorstajekoztato msa l figyelmeztetes a gyorstajekoztato nem helyettesiti a hasznalati utasitast. Msa altair 4xr bluetooth multigas detector 4 gas lel,co,o2. The altair 4x is built for lel, co, h2s, and o2 applications. The real strength of the altair 4x multigas detector comes from the sensor technology. Msa mine safety appliances 10110444 charcoal altair 4x portable combustible gas and oxygen monitor with rechargeable battery and motion alert, english, 30. Once the msa altair 4 and msa altair 4x is in normal reading mode, you need to send it into calibration mode. The altair 4x is an extremely durable multigas detector that simultaneously measures up to four gases from a wide range of xcellr sensor options including combustible gases, o. Innovation has been an ongoing differentiator for msa, and i am pleased to. At msa, we work tirelessly to build smarter, better gas detection instruments that people across the world rely on.

Want to calibrate the msa altair 4 or msa altair 4x. Altair 4x msha multigas detector instruction manual in north america, to contact your nearest stocking location, dial tollfree 1800 msa 2222 to contact msa international, dial 7247768626 or 1800 msa 7777. Outfitted with rapidresponse msa xcell sensors, the altair 4xr gas detector is the toughest 4gas monitor on the market and is backed by a 4year warranty. Altair 5x gas detector natural gas and pid msa safety. How to setchange date and time on msa altair 44x youtube. The views and opinions of authors expressed herein do not necessarily reflect those of the.

Msa altair 4x gas detector 4 gas monitor perfect for various industries. Msa 467895 rp flow control regulator for altair 4x and 4xr. Assess potential worker exposure to combustibl e and toxic gases and vapors as well as low level of oxygen. Msa altair 4x buy replacement parts and accessories. Multigas monitors have sensors that need replacing every so often. Altair 4x multigas detector cross reference factors.

Msa altair 4x gas detector 4 gas monitor that simultaneously measures up to 4 gases. Based on the costefficient design of its diffusion based gas detectors, msa is able to use 0,25 lpm regulators. This video from ideal calibrations walks you through how to change the date and time on the msa altair 44x. The altair 4xr can also provide realtime incident awareness to team members, supervisors, safety managers and others when paired with the msa altair connect app via a bluetooth. Combustible gas detector sensor drift energy improvement. Msa 10152669 pump probe for altair 4x4xr with charger. The xl version has two paper patterns and a pdf pattern and about twice the materials. While you can always send the monitor to a repair center for maintenance, you can also le. The altair 5x gas detector is capable of measuring up to 6 gases simultaneously and is now available with integrated pid sensor for voc detection.

Turn the msa altair 4 and msa altair 4x on in normal reading mode. Cylinder of calibration gas blended to match levels for the msa altair 4x gas detector. Learn how your data is used with cookies to preserve your experience, and optin to customize your experience. This versatile portable detector is a perfect match for industries ranging from fire fighting to welding, and its digital sensor output makes it less likely to suffer from rf. The real strength of the altair 4x multigas detector comes from new sensor te chnology. Camera alphabelt rescue and holding belt altair 4xr multigas.

Altair 2x 3 declaration of conformity us declaration of conformity the manufacturer or the european authorized representative. Msa safety sales, llc10106729 altair 4x and altair 5x oxygen sensor. The altair 4x is an extremely durable multigas detector that simultaneously measures up to four gases from a wide range of xcell sensor options including combustible gases, o. Msa is a global organization committed to developing, manufacturing, and supplying safety products that help protect people and facility infrastructures around the world. Housed in a rugged ip68rated exterior, and tested to survive 25 drops from heights of around 4 feet high, the altair 4xr has been designed to be durable enough to withstand 1 drop from 25 feet. It is designed to be used when performing a hazard assessment to.

Capable of drawing samples from up to 50ft 15m away, quickly convert diffusion instruments for use in remote sampling applications. Msa altair 4xr bluetooth multigas detector 4 gas lel,co. Shop for a number of spare parts and accessories for the msa altair 4x multi gas detector. Altair 4xr gas multi gas detector msa safety africa. Msa declaration of conformity gb altair 5x altair 5x ir 3 declaration of conformity manufactured by. Assess potential worker exposure to combustible and toxic gases and vapors as well as low level of oxygen. Msa altair 4x gas detector msa safety united states. The altair pump probe is a rugged sampling accessory for msa gas detection instruments. Box 427, pittsburgh, pennsylvania 15230 l rev 2 imz001034 10074734 in north america, to contact your nearest stocking location, dial tollfree 1800 msa 2222. Altair 4x multigas detector with msa xcell sensor technology altair 4x detector with 3year warranty, data logging, charger, calibration cap and tubing approvals u. Il sistema di registrazione dei dati e fornito come standard.

With altair 2x, altair 4x and altair 5x gas detectors, msa has developed the most advanced technology available in any portable gas detector on the market with xcell sensor technology. Technology offers durability and performance for mining applications. Dependable multigas detector tests for lel, oxygen, carbon monoxide, and hydrogen sulfide. Msa s network of distributors can help find the right product for you. Altair 4x multigas detector cross reference factors addendum. Msa instrument safety altair 4 operating manual 5 1 instrument safety 1. Altair 4x compact multigas detector powered by msa xcell sensors. Evaluation of lowcost hydrogen sulfide monitors for use in.

Msa altair 4xr 5 things you need to know frontline safety. Msa altair 4x has a fouryear sensor life which is 60% longer than the industry average, while its 24hour run time exceeds the industry average by 71%. The ultralong battery life keeps the focus on safety and less on maintenance. The newer model has sensors that are 2 x faster than the industry average.

Methaneoptimized catalytic bead sensor provides increased stability over time. Determine the appropriate gas and vapor monitoring needed for a workplace. Combustible gas cross reference factors for altair 4x generalpurpose calibration using calibration cylinder pn 10045035 set to 58% lel. Suppliedair respirators airpurifying respirators portable gas detection. Nov 01, 2012 msa xcell to digital output, this sensor is not backwardscompatible withsensors are designed for longer life, faster response, and higher older msa instruments, but instead establishes msa s futureperformance when used with msa s altair 4x multigas product platform. Laccesso alla modalita di configurazione e protetto da password. They have msa xcell sensors allowing for double the typical life than the industry standard.

Msa has designed and manufactured gas detection historically. By simply pressing control module, firefighters can send manual confirmation to. Msa altair 4xr operating manual pdf download manualslib. Product information sheet furnished by sony for lithium ion cell used in the altair 4, altair 4x, and altair 4xr. Msa 10152669 altair 50ft sample draw pump probe with charger. Msa auer gmbh thiemannstrasse 1 d12059 berlin declares that the product altair 2x based on the ectype examination certificate.

For your local msa contacts please go to our website. The altair 4x is versatile, rugged in design and has the ability to withstand a drop of 6 metres and economically uses less than half as much calibration gas as the industry average. This versatile portable detector is a perfect match for. Safety regulations msa 6 altair 4x gb 1 safety regulations 1. The altair 4xr multigas detector is for use by trained and qualified personnel.

Ftzu atex 0200 x complies with the atex direct ive 949ec, annex iii. Msa altair 4x multigas detector bump test procedure. Altair 4xr 5 safety regulations us 1 safety regulations 1. Msa altair 4x gas detector msa safety united kingdom. The altair io360 combines the simple setup of a smart home device, while allowing local or remote monitoring of hazardous areas. See the sellers listing for full details and description of any imperfections. For construction and shipyard workers, exposures to h2s must be maintained below. Operating manual altair 5x multi gas detector altair 5x. The altair 4x multigas detector can be equipped to detect. Msa altair 5x gas detector measures up to 6 gases including natural gas.

Altair 4x multigas detector powered by msa xcell sensors the altair 4x is a reliable multigas detector that simultaneously measures up to four gases from a wide range of sensor options including combustible gases, o. Its fouryear sensor life is 60% longer than the industry average, while its 24hour run time exceeds the industry average by 71%. Altair 4 kits, 4gas in black case with calibration cylinder and 0. Altair 4x multigas detectors offers durability and new sensor technology. Msa altair 4x multigas detector portable gas detection. The altair 4x multigas detector surpasses industry standards in several crucial areas. Msa altair 4x multigas detector 10107602 for lel, oxygen, hydrogen sulfide and carbon monoxide with motion alert. Box 427, pittsburgh, pennsylvania 15230 l rev 2 imz001034 10074734 in north america, to contact your nearest stocking location, dial tollfree 1800 msa. Do this by pressing and holding right up button until it beeps at you and the screen asks you to zero the monitor. Msa xcell sensors are designed for an average life of more than four years and are engineered using msa s proprietary applicati onspecific integrated circuit asic design. Although the msa altair 4x has been replaced by the msa altair 4xr, spare parts and accessories are still available. New msa altair 4x msha multigas detector is optimized for miners. Can atex anz coniguration case color 10107602 10110453 10110447 lel, o 2, co, h 2s charcoal 10107603 10110456 10110450 lel, o 2, co, h 2s phosphorescent. Regulators are used to ensure you receive the required flow of calibration gas for your application.

Operating manual altair 5x multi gas detector altair 5x ir. Combustible gas type can be changed manually through the sensor setup menu or the msa link software. Rendkivul fontos, hogy elolvassa es a keszulek hasznalata kozben betartsa a cdlemezen levo hasznalati utasitast. Summary of contents for msa altair 4x page 1 operating manual altair multigas detector order no. The altair io360 delivers ip68 ruggedness and bestinclass, xcell sensors, the performance expected from msa. Msa xcell sensors are a breakthrough in chemical and mechanical sensor design, enabling faster response and span calibration times. The altair 4x can be calibrated manually using this procedure or automatically using the galaxy test stand. Catalytic bead combustible sensor technology dates to the 1830s and has been used for decades to measure concentrations of many combustible gases. Choose from replaceable parts such as sensors and clips and accessories such as pump probes and chargers. Msa altair 4xr 5 things you need to know frontline. Gas detection portable respiratory protection blackwoods. As indicated in user manual provided with monitor at time of purchase.

1454 1565 1097 966 129 787 57 825 688 611 409 527 897 686 162 707 1491 1893 1389 1243 872 584